<LOGO>
FM Transmitter Measurement Report
Created: 2025-06-15 17-24-32
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 49 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 71 kHz 7722 7,2650
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,26 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 17 kHz % above 76 kHz: 7,2650 Acquired: 2025/06/15 17.23.28 Total samples: 7722 Equivalent time: 0:06:26 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 6,2 dBr MIN: 3,9 dBr AVE: 5,26 dBr % above 12,2 dBr: 0,0 Last value: 5,1 dBr (2025/06/15 17.23.28) 17.10 17.12 17.14 17.16 17.18 17.20 17.22 0 2 4 6 Pm [dBr]